A grounding wire or bonding jumper should be installed across horizontal cable tray expansion joints to maintain electrical continuity and ensure safety. Purpose of Grounding at Expansion JointsExpansion joints in cable trays allow for thermal expansion and contraction of the tray system. However, these joints create a mechanical gap that can interrupt the electrical continuity of the tray.

To maintain a low-impedance path for fault currents and ensure the tray functions as an Equipment Grounding Conductor (EGC), a bonding jumper or grounding wire is required across the joint.

Recommended Practices

Use a properly sized grounding wire: The wire should meet or exceed the minimum cross-sectional area requirements specified in NEC Article 392.60 for the tray's ampacity. For example, aluminum trays should not use bare copper due to corrosion; insulated conductors with exposed ends at bonding points are preferred. Attach to both sides of the expansion joint: The grounding wire should be securely connected to each tray section using UL-listed grounding clamps or bonding connectors.

This ensures mechanical stability and electrical continuity. Maintain electrical continuity: Even if the tray is mechanically continuous, the bonding jumper ensures the tray remains electrically continuous across the expansion joint, which is critical for fault current clearing and safety. Follow manufacturer and NEMA guidelines: Many cable tray systems, such as Snap Track or Flextray, provide UL-classified bonding connectors and recommend grounding jumpers specifically at expansion plates or adjustable fittings.

Additional Considerations

Avoid bare copper in aluminum trays to prevent electrolytic corrosion; use insulated conductors with tin or zinc-plated connectors. Check ampacity limits: Some trays can serve as the EGC only up to certain amperages (e.g., Snap Track 4” and 6” trays up to 1000 A; 2” trays up to 600 A). For higher currents, a separate EGC is required.

Secure cables before and after the joint: This prevents movement that could stress the grounding connections.

Summary

For horizontal cable tray expansion joints, install a bonding jumper or grounding wire across the joint, attach it securely to both tray sections using approved connectors, and ensure the conductor meets NEC sizing requirements. This maintains electrical continuity, supports fault current paths, and complies with safety standards.

Research context

Reference summary

Cable tray manual Instead of large conduits, cable channel may be used very effectively to support cable drops from the cable tray run to the equipment or.

From reference to enquiry

Questions for your project

Use these editorial prompts alongside the linked excerpts. They identify items to confirm for your project.

Technical notes

Illustrative equipment image

Cable tray manual

Instead of large conduits, cable channel may be used very effectively to support cable drops from the cable tray run to the equipment or device being serviced and is ideal for cable tray runs involving a

NEMA Standards Publication VE 2-2018

A fitting for wire mesh cable tray systems, fabricated from wire mesh cable tray straight sections. The fitting is field-constructed and attached to the adjacent sections using splice connectors in

Equipment Grounding Conductors for Cable Tray Systems

The intent of this article is to review grounding practices for cable tray wiring systems. The Equipment Grounding Conductors are the most important conductors in the electrical systems. The Equipment

Practices for grounding and bonding of cable trays

All metallic cable trays shall be grounded as required in Article 250.96 regardless of whether or not the cable tray is being used as an equipment

Cable Tray Installation Rules (NEC 392) – Electrical Trader

Core rules for selecting, installing, grounding, and filling cable trays—clearances, materials, separation, and bonding explained.

INSTALLATION GUIDE

Where metal supports for metal cable trays are bolted to the tray and are in good electrical contact with the grounded structural metal frame of a building, the tray shall be deemed to be bonded to ground.

Cable Tray Technical Guide A practical guide to product selection and

Where single-conductor cables comprising each phase, neutral or grounded conductor of an alternating-current circuit are connected in parallel, the conductors shall be installed in groups consisting of not

GUIDE CABLE TRAYS TECHNICAL

NEMA VE 1-2017 Specifies requirements for metal cable trays and associated fittings designed for use in accordance with the rules of Canadian Electrical Code, Part I and the National Electrical Code®

Cable Tray Grounding Wire: What You Need to Know

Discover the best practices for Cable Tray Grounding Wire installation. Learn key requirements, safety tips, and material choices to ensure a

Equipment Grounding Conductors for Cable Tray Systems

Equipment Grounding Conductors for Cable Tray Systems Cable tray wiring systems have excellent safety and dependability records. These excellent records are the result of cable tray''s unique

Practices For Grounding and Bonding of Cable Trays

The document discusses grounding and bonding practices for metallic and non-metallic cable trays. Metallic cable trays must be grounded and can serve as an equipment grounding conductor if the

MP Husky Cable Tray Catalog.pdf

Note that the bolt head is mounted on the inside wall of the cable tray to avoid damage to the cable insulation. Grounding connectors may be used with aluminum or galvanized steel cable trays and

Cable Tray Installation Guide | NEMA VE 2-2018

NEMA VE 2-2018 Cable Tray Installation Guidelines. Learn best practices for cable tray installation, support, and accessories.

Electrical cable Tray Installation Details with Support Systems

Key features include cross-sections of tray-to-conduit transitions, multi-layer offset configurations (with both, basically, single and double branch variants), and specialized expansion joint details with

B-Line series Cable Tray Design Considerations

Is your cable tray system optimized for safety, dependability, space and cost savings? Cable tray (or cable ladder) systems are a popular alternative to electrical conduit systems, as they have an

Grounding Inspection of Steel and Aluminum Cable Tray Systems

For safety reasons, the grounding should be right before the wire is energized. This is true for cable tray, conduit, cable, or any electrical system. The grounding inspection should start with the installation

Best Practice Guide to Cable Ladder and Cable Tray Systems

This guide covers cable ladder systems, cable tray systems, channel support systems and associated supports intended for the support and accommodation of cables and possibly other electrical

Practices for Grounding and Bonding of Cable Trays

Practices for Grounding and Bonding of Cable Trays Grounding and bonding of cable trays (on photo: Ground wire connected to cable tray; photo credit: solarprofessional )

Related Video Reference

This video was associated with the source search result. Verify technical details against current product documentation and project requirements.

Share your network requirements

Share the fiber interfaces, termination capacity, cable route and evidence required for handover.

Send a project brief